SolarEdge
50 cited fault codes · owned by SolarDesk.
| Code | Title | Severity | Confidence | Citations |
|---|---|---|---|---|
| 18x17 | Main capacitor error | stop | verified | 1 |
| 18x37 | V-Line max (line-to-line over-voltage) | degraded | verified | 1 |
| 18x6F | AC current surge (three-phase) | degraded | verified | 1 |
| 18x76 | Temperature too low | degraded | verified | 1 |
| 18x7B | MainError (grid measurements out of range) | degraded | verified | 1 |
| 18x7F | IRCDMax (RCD current surge) | stop | verified | 1 |
| 18x85 | Temperature sensor fault | degraded | verified | 1 |
| 18x86 | Isolation fault (single-phase, 18x86) | stop | verified | 1 |
| 18xC7 | Rapid shutdown (RSD) error | stop | verified | 1 |
| 2x10 | Hardware error | stop | verified | 1 |
| 2x11 | Temperature too high | degraded | verified | 1 |
| 2x18 | Faulty temperature sensor | degraded | verified | 1 |
| 2x19 | Isolation fault | stop | verified | 1 |
| 2x1A | Faulty AC relay | stop | verified | 1 |
| 2x1C | RCD sensor error | stop | verified | 1 |
| 2x1F | AC voltage too high (line 1/2/3) | degraded | verified | 1 |
| 2x20 | AC voltage too low | degraded | verified | 1 |
| 2x22 | AC frequency too high (line 1/2/3) | degraded | verified | 1 |
| 2x23 | AC frequency too low (line 1/2/3) | degraded | verified | 1 |
| 2x24 | DC injection (line 1/2/3) | stop | verified | 1 |
| 2x28 | Islanding | degraded | verified | 1 |
| 2x2C | No country selected | stop | verified | 1 |
| 2x86 | DSP1-DSP2 VDC difference max | stop | verified | 1 |
| 2x9 | AC current surge | degraded | verified | 1 |
| 2x98 | Arc detector self-test failed | stop | verified | 1 |
| 2xA | Ground current / RCD trip | stop | verified | 1 |
| 2xC5 | Rapid shutdown (RSD) error | stop | verified | 1 |
| 2xE | AC voltage too high (line 1/2/3) | degraded | verified | 1 |
| 2xF | DC voltage too high (surge) | stop | verified | 1 |
| 3x11 | Arc fault detected | stop | verified | 1 |
| 3x2 | Software (SW) error | stop | verified | 1 |
| 3x6D | Internal RGM error | degraded | verified | 1 |
| 3x6E | Energy meter communication error | degraded | verified | 1 |
| 3xB | No country selected (three-phase) | stop | verified | 1 |
| 8x10 | Communication error | degraded | verified | 1 |
| 8x19 | AC voltage too high (three-phase, line 1/2/3) | degraded | verified | 1 |
| 8x1C | AC voltage too low (three-phase) | degraded | verified | 1 |
| 8x2B | Ground current / RCD trip (three-phase) | stop | verified | 1 |
| 8x2D | Grid sync error | degraded | verified | 1 |
| 8x34 | DC voltage too high (surge, three-phase) | stop | verified | 1 |
| 8x36 | Islanding - active | degraded | verified | 1 |
| 8x38 | Islanding - passive | degraded | verified | 1 |
| 8x3A | AC over-current (line 1/2/3) | stop | verified | 1 |
| 8x42 | AC voltage too high (line 1/2/3, three-phase) | degraded | verified | 1 |
| 8x45 | UDC max (DC input over-voltage) | stop | verified | 1 |
| 8x46 | UDC min (DC input under-voltage) | stop | verified | 1 |
| 8x4F | Wrong AC connection | stop | verified | 1 |
| 8x51 | RCD current surge | stop | verified | 1 |
| 8x58 | Isolation fault (three-phase) | stop | verified | 1 |
| 8xB8 | Pairing error | stop | verified | 1 |