3x11 — SolarEdge
Arc fault detected
severity: stopconfidence: verifiedkind: error1 citation(s)
Scope: SolarEdge single-phase and three-phase inverters (Europe & APAC)
Meaning
The inverter's arc-fault detector tripped: a DC arc was detected in the PV array. SolarEdge refers the installer to its arc-fault detection application note for the inspection and repair procedure.
Likely causes
- Series or parallel DC arc in a string connector or cable
- Damaged module junction box or optimizer lead
- Loose DC connector under load
Checks
- Follow the arc-fault detection application note before re-energising
- Inspect string connectors, optimizer leads and module junction boxes for arcing
- Repair or replace the damaged DC component; do not reset repeatedly
Safety flags
- dc_arc
- pv_dc
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- DC connectors
- power optimizers
- PV modules
Citations
type: manual · retrieved: 2026-11-21 · locator: p. 5
Arc Fault Detected Refer to http://www.solaredge.com/sites/default/files/arc_ fault_detection_application_note.pdf