2x9 — SolarEdge
AC current surge
severity: degradedconfidence: verifiedkind: error1 citation(s)
Scope: SolarEdge single-phase and three-phase inverters (Europe & APAC)
Meaning
The inverter logged a surge on the AC current input, shown together with a Vac surge. The addendum says a ground current surge can be involved and tells you to check the AC connection to the inverter and to ask the grid operator about large surge sources or irregular loads near the site.
Likely causes
- AC voltage/current surge on the grid
- Irregular load or large surge source near the site
- Loose or damaged AC connection
Checks
- Check the AC connection to the inverter
- Ask the grid operator whether a large surge source or irregular load exists near the site
- If the grid is clean, contact SolarEdge Support
Safety flags
- grid_tie
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- AC wiring