8x4F — SolarEdge
Wrong AC connection
severity: stopconfidence: verifiedkind: error1 citation(s)
Scope: SolarEdge single-phase and three-phase inverters (Europe & APAC)
Meaning
The inverter reports that its AC connection is wrong: one phase is landed on the wrong terminal. The addendum's remedy is to switch between L1 and L2, or between L2 and L3, connections.
Likely causes
- L1 and L2 AC conductors swapped at the terminal block
- L2 and L3 AC conductors swapped at the terminal block
Checks
- Isolate the AC supply and confirm the L1/L2/L3 landing against the installation guide
- Swap L1 with L2, or L2 with L3, as required and re-commission the inverter
Safety flags
- grid_tie
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- AC terminal block
- AC wiring
Citations
type: manual · retrieved: 2026-11-21 · locator: p. 1
Wrong AC connection Switch between L1 and L2 or L2 and L3 connections
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.