8x34 — SolarEdge
DC voltage too high (surge, three-phase)
severity: stopconfidence: verifiedkind: error1 citation(s)
Scope: SolarEdge single-phase and three-phase inverters (Europe & APAC)
Meaning
A three-phase inverter saw a DC input over-voltage (codes 8x34/8x35/8x37), normally a surge that the SolarEdge system should clear. If it persists, isolate, wait five minutes and locate the malfunctioning string.
Likely causes
- PV string too long for the DC input range
- Power optimizer failure
- DC surge or loose string connection
Checks
- Switch the inverter OFF, wait five minutes and check the safety voltage
- Locate the malfunctioning string and recheck its connections
- Follow the Power Optimizer Troubleshooting section of the installation guide
Safety flags
- dc_arc
- grid_tie
- pv_dc
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- PV strings
- power optimizers
Citations
type: manual · retrieved: 2026-11-21 · locator: p. 2
DC Voltage Too High (surge) The SolarEdge system normally eliminates DC overvoltage errors.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.