8x36 — SolarEdge
Islanding - active
severity: degradedconfidence: verifiedkind: error1 citation(s)
Scope: SolarEdge single-phase and three-phase inverters (Europe & APAC)
Meaning
The inverter detected an active islanding condition (AC grid voltage malfunction) and stopped producing. It restarts after the reconnection time when AC voltage returns; if the problem persists, consult the grid operator.
Likely causes
- Grid outage or voltage malfunction
- Upstream protection or breaker open
Checks
- Check the grid supply at the main connection point
- Wait for the reconnection time after the grid returns
- Consult the grid operator if it persists
Safety flags
- dc_arc
- grid_tie
Citations
type: manual · retrieved: 2026-11-21 · locator: p. 4
Islanding - Active AC grid voltage malfunction. When AC voltage returns the inverter should restart after the reconnection time.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.