Ground current / RCD trip (three-phase)
severity: stopconfidence: verifiedkind: error1 citation(s)
Scope: SolarEdge single-phase and three-phase inverters (Europe & APAC)
Meaning
A three-phase inverter detected a ground-fault current (codes 8x2B/8x2C/8x39 share this row). The addendum attributes it to insufficient insulation to ground and requires the string-by-string isolation procedure by a qualified technician.
Likely causes
- Damaged or degraded module insulation
- Damaged DC string cable or connector
- Moisture creating a leakage path to earth
Checks
- Switch the inverter off, wait five minutes, then disconnect AC and DC
- Reconnect DC strings one at a time until the fault reappears
- Leave the faulty string disconnected for a certified installer to repair
Safety flags
- dc_arc
- grid_tie
- pv_dc
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- PV modules
- DC cabling
- RCD
Citations
type: manual · retrieved: 2026-11-21 · locator: p. 2
Ground Current - RCD Ground faults may occur due to insufficient insulation to the ground.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.