2x23 — SolarEdge
AC frequency too low (line 1/2/3)
severity: degradedconfidence: verifiedkind: error1 citation(s)
Scope: SolarEdge single-phase and three-phase inverters (Europe & APAC)
Meaning
The inverter measured an AC grid frequency below the lower limit of the selected country grid code and disconnected. The addendum lists the message without a field repair; investigate the grid supply and the country setting.
Likely causes
- Grid frequency excursion below the country limit
- Wrong country/grid-code setting
- Weak or islanded grid supply
Checks
- Confirm the country/grid-code setting
- Consult the grid operator about the frequency event
- Check for a local generator or islanding condition
Safety flags
- dc_arc
- grid_tie
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- AC wiring
Citations
type: manual · retrieved: 2026-11-21 · locator: p. 3