2xA — SolarEdge
Ground current / RCD trip
severity: stopconfidence: verifiedkind: error1 citation(s)
Scope: SolarEdge single-phase and three-phase inverters (Europe & APAC)
Meaning
A residual-current (ground-fault) event was detected. The addendum explains that ground faults may occur when insulation to ground is insufficient, warns of electric shock hazard inside the cover, and gives a string-by-string procedure that only a qualified technician may carry out.
Likely causes
- Damaged or degraded module insulation
- Damaged DC string cable or connector
- Moisture or soiling creating a leakage path to earth
Checks
- Turn the inverter ON/OFF switch to OFF and wait five minutes for the input capacitors to discharge
- Disconnect the AC breaker and the DC inputs
- Reconnect one DC string at a time until the error reappears to identify the faulty string
- Do not reconnect a string with a ground fault; a certified installer must repair it first
Safety flags
- dc_arc
- pv_dc
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- PV modules
- DC cabling
- RCD
Citations
type: manual · retrieved: 2026-11-21 · locator: p. 2
Ground Current - RCD Ground faults may occur due to insufficient insulation to the ground.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.