2xF — SolarEdge
DC voltage too high (surge)
severity: stopconfidence: verifiedkind: error1 citation(s)
Scope: SolarEdge single-phase and three-phase inverters (Europe & APAC)
Meaning
The DC input voltage from the PV array exceeded the inverter's limit, usually as a surge. SolarEdge notes its system normally eliminates DC over-voltage errors; if the fault persists, switch the inverter off, wait five minutes and check which string is malfunctioning and its connections.
Likely causes
- PV string too long for the inverter's DC input range
- Power optimizer failure or bypassed optimizer
- DC surge or loose string connection
Checks
- Turn the inverter ON/OFF switch OFF and wait five minutes
- Check whether the LCD shows the expected low safety voltage (about 1 V per optimizer)
- Identify the malfunctioning string and recheck its connections to the inverter
- Follow the Power Optimizer Troubleshooting section of the installation guide
Safety flags
- dc_arc
- pv_dc
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- PV strings
- power optimizers
- DC cabling
Citations
type: manual · retrieved: 2026-11-21 · locator: p. 2
DC Voltage Too High (surge) The SolarEdge system normally eliminates DC overvoltage errors.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.