8x58 — SolarEdge
Isolation fault (three-phase)
severity: stopconfidence: verifiedkind: error1 citation(s)
Scope: SolarEdge single-phase and three-phase inverters (Europe & APAC)
Meaning
Three-phase inverters report the isolation fault as code 8x58. The PV array is not properly isolated from earth; check the installation for isolation problems and ground leakage, and have a certified installer fix the string.
Likely causes
- Damaged module insulation
- Damaged DC string cable or connector
- Moisture or soiling leakage path
Checks
- Check the PV installation for isolation problems and ground leakage
- Isolate strings one at a time to locate the fault
- Only a certified PV installer may repair and reconnect the faulty string
Safety flags
- dc_arc
- grid_tie
- pv_dc
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- PV modules
- DC cabling
Citations
type: manual · retrieved: 2026-11-21 · locator: p. 3
Isolation Fault PV solar array is not properly isolated from ground earth.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.