18x86 — SolarEdge
Isolation fault (single-phase, 18x86)
severity: stopconfidence: verifiedkind: error1 citation(s)
Scope: SolarEdge single-phase and three-phase inverters (Europe & APAC)
Meaning
Single-phase inverters report the isolation fault as code 18x86 (the same row lists 2x19 and 8x58). The PV array is not properly isolated from earth, and only a certified PV installer may repair the faulty string.
Likely causes
- Damaged module insulation
- Damaged DC string cable or connector
- Moisture path to earth
Checks
- Read the isolation resistance on the inverter status screen
- Isolate and test string by string to find the leakage
- Have a certified PV installer repair the faulty string
Safety flags
- dc_arc
- grid_tie
- pv_dc
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- PV modules
- DC cabling
Citations
type: manual · retrieved: 2026-11-21 · locator: p. 3
Isolation Fault PV solar array is not properly isolated from ground earth.