2x20 — SolarEdge
AC voltage too low
severity: degradedconfidence: verifiedkind: error1 citation(s)
Scope: SolarEdge single-phase and three-phase inverters (Europe & APAC)
Meaning
The AC grid voltage the inverter measures is below the limit for the selected country. The addendum's remedy is to verify that the inverter is set to the correct country, then to consult the grid operator.
Likely causes
- Grid under-voltage or a weak grid connection
- Inverter set to the wrong country/grid code
- Undersized or damaged AC cable causing voltage drop
Checks
- Verify that the inverter is set to the correct country
- Consult the grid operator about the supply voltage
- Check the AC cable size and terminations against the installation guide
Safety flags
- grid_tie
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- AC wiring
Citations
type: manual · retrieved: 2026-11-21 · locator: p. 3
AC Voltage Too Low Verify that the inverter is set to the correct country.