8x51 — SolarEdge
RCD current surge
severity: stopconfidence: verifiedkind: error1 citation(s)
Scope: SolarEdge single-phase and three-phase inverters (Europe & APAC)
Meaning
A residual-current surge was detected on the DC side, which usually means a ground-fault/insulation problem in the PV array. SolarEdge points to its isolation-fault troubleshooting application note and to support.
Likely causes
- Insufficient insulation to ground in the PV array
- Damaged DC cable or connector
- Water ingress in a junction or optimizer
Checks
- Follow the isolation-fault troubleshooting application note
- Isolate and test string by string to locate the leakage
- Contact SolarEdge support if the fault persists
Safety flags
- dc_arc
- pv_dc
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- PV modules
- DC cabling
- RCD
Citations
type: manual · retrieved: 2026-11-21 · locator: p. 4
RCD Current Surge Refer to: www.solaredge.com/files/pdfs/application_note_ isolation_fault_troubleshooting.pdf Contact SolarEdge support.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.