2x1F — SolarEdge
AC voltage too high (line 1/2/3)
severity: degradedconfidence: verifiedkind: error1 citation(s)
Scope: SolarEdge single-phase and three-phase inverters (Europe & APAC)
Meaning
The grid voltage on one AC line rose above the country limit, so the inverter tripped. The addendum says to verify the country setting, turn the site's inverters off and verify the AC grid voltage, use a larger gauge AC wire on long runs, consult the grid operator and, where permitted, change the grid protection values.
Likely causes
- Grid over-voltage above the country limit
- Inverter set to the wrong country
- Voltage rise on an undersized AC cable
Checks
- Verify the inverter is set to the correct country
- Turn off the site's inverters and measure the AC grid voltage
- Use a larger gauge AC wire if the inverter is far from the grid connection point
- Consult the grid operator and change grid protection values only where local rules permit
Safety flags
- grid_tie
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- AC wiring
Citations
type: manual · retrieved: 2026-11-21 · locator: p. 3
AC Voltage Too High (Line 1/2/3) Grid voltage is above the country limit.