2xE — SolarEdge
AC voltage too high (line 1/2/3)
severity: degradedconfidence: verifiedkind: error1 citation(s)
Scope: SolarEdge single-phase and three-phase inverters (Europe & APAC)
Meaning
An AC voltage surge drove the grid voltage above the permitted level, so the inverter tripped. The addendum advises checking the AC connection, confirming the country setting, checking with the grid operator and using a larger gauge AC wire where the inverter is far from the grid connection point.
Likely causes
- Grid over-voltage or voltage surge
- Inverter set to the wrong country/grid code
- Voltage rise on a long, undersized AC run
Checks
- Check the AC connection to the inverter
- Verify the inverter is set to the correct country
- Check with the grid operator for surge sources or irregular loads near the site
- Use a larger gauge wire for the AC output if the run is long
Safety flags
- grid_tie
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- AC wiring
Citations
type: manual · retrieved: 2026-11-21 · locator: p. 2
AC Voltage Too High (Line 1/2/3) AC voltage surge.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.