8x46 — SolarEdge
UDC min (DC input under-voltage)
severity: stopconfidence: verifiedkind: error1 citation(s)
Scope: SolarEdge single-phase and three-phase inverters (Europe & APAC)
Meaning
The DC input voltage (UDC) fell below the inverter's minimum, so it cannot operate. The addendum has no field repair and directs you to contact SolarEdge support.
Likely causes
- String voltage below the inverter's minimum
- Optimizer or string wiring fault
- Low irradiance or a disconnected string
Checks
- Check the DC voltage and string count on the status screen
- Confirm all strings are connected and producing
- Contact SolarEdge support if the voltage is low in full sun
Safety flags
- dc_arc
- pv_dc
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- PV strings
- power optimizers
Citations
type: manual · retrieved: 2026-11-21 · locator: p. 5
UDC Min Contact SolarEdge support.