SMA

53 cited fault codes · owned by SolarDesk.

CodeTitleSeverityConfidenceCitations
1001L / N swappedstopverified1
101Grid incident - grid voltage or grid impedance too highdegradedverified1
102Grid incident - grid voltage or grid impedance too highdegradedverified1
103Grid incident - grid voltage or grid impedance too highdegradedverified1
104Grid incident - grid voltage or grid impedance too highdegradedverified1
105Grid incident - grid voltage or grid impedance too highdegradedverified1
1101Installation fault - check connectionstopverified1
1302Waiting for grid voltage - grid connection installation errorstopverified1
1501Reconnection fault griddegradedverified1
202Grid incident - utility grid down / AC cable damaged / grid voltage too lowdegradedverified1
203Grid incident - utility grid down / AC cable damaged / grid voltage too lowdegradedverified1
205Grid incident - utility grid down / AC cable damaged / grid voltage too lowdegradedverified1
206Grid incident - utility grid down / AC cable damaged / grid voltage too lowdegradedverified1
301Grid incident - ten-minute average grid voltage exceededdegradedverified1
302Temperature AC voltage - power limited by high grid voltagewarningverified1
3303Unstable operationwarningverified1
3501Insulation failure - check generatorstopverified1
3601High leakage current - check generatorstopverified1
3701Residual current too high - check generatorstopverified1
3801Residual current too high - check generator (DC overcurrent)stopverified1
3802Residual current too high - check generator (DC overcurrent)stopverified1
3901Waiting for DC start conditions - start conditions not metwarningverified1
3902Waiting for DC start conditions - start conditions not metwarningverified1
401Grid incident - stand-alone grid or large frequency changedegradedverified1
404Grid incident - stand-alone grid or large frequency changedegradedverified1
501Grid incident - grid frequency out of rangedegradedverified1
507Temperature AC frequency - power limited by high frequencywarningverified1
601Grid incident - DC proportion in grid current too highdegradedverified1
6501Self-diagnosis - overtemperaturedegradedverified1
6502Self-diagnosis - overtemperaturedegradedverified1
6509Self-diagnosis - overtemperaturedegradedverified1
6512Minimum operating temperature not reachedwarningverified1
6603Self-diagnosis - overcurrent grid / overvoltage intermediate circuitstopverified1
6604Self-diagnosis - overcurrent grid / overvoltage intermediate circuitstopverified1
6801Self-diagnosis - input A / input B defective (polarity error)stopverified1
6802Self-diagnosis - input A / input B defective (polarity error)stopverified1
6901Self-diagnosis - input A / input B defective (polarity error)stopverified1
6902Self-diagnosis - input A / input B defective (polarity error)stopverified1
7001Fault sensor interior temperaturestopverified1
7002Fault sensor interior temperaturestopverified1
701Frequency not permitted - check parameterdegradedverified1
7701Self-diagnosis - interference devicestopverified1
7702Self-diagnosis - interference devicestopverified1
7703Self-diagnosis - interference devicestopverified1
8003Temperature deratingwarningverified1
8708Timeout in communication for active power limitationwarningverified1
8709Timeout in communication for reactive power / cos phi setpointwarningverified1
8710Timeout in communication for reactive power / cos phi setpointwarningverified1
9002SMA Grid Guard code invalidwarningverified1
9003Grid parameter lockedinfoverified1
9007Abort self-testwarningverified1
901PE connection missing - check connectionstopverified1
9101AC voltage calibration failedstopverified1