701 — SMA
Frequency not permitted - check parameter
severity: degradedconfidence: verifiedkind: error1 citation(s)
Scope: SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)
Meaning
The grid frequency is not within the permissible range, so the inverter has disconnected from the utility grid. Unlike event 501, SMA additionally asks the installer to check the AC wiring between the inverter and the feed-in meter, and to get the grid operator's approval before changing operating parameters.
Likely causes
- Grid frequency outside the permissible range
- AC wiring fault between the inverter and the feed-in meter
- Operating parameters not matching the local grid code
Checks
- Check the AC wiring from the inverter to the feed-in meter
- Check the grid frequency and observe how often fluctuations occur
- If the message appears often, ask the grid operator to approve a change of the operating parameters
Safety flags
- grid_tie
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- AC wiring
- feed-in meter
Citations
https://files.sma.de/downloads/STP3-6-3AV-40-BE-en-22.pdf
type: manual · retrieved: 2026-11-21 · locator: p. 87
Explanation: The grid frequency is not within the permissible range. The inverter has disconnected from the utility grid.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.