8708 — SMA
Timeout in communication for active power limitation
severity: warningconfidence: verifiedkind: error1 citation(s)
Scope: SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)
Meaning
Communication to the system control is absent, so the inverter falls back either to the last received values or to a fixed percentage of its nominal power for active power limitation. SMA asks for the connection to the system manager to be checked for damage and pulled plugs.
Likely causes
- System manager offline or unreachable
- Damaged or disconnected communication cable
- Network fault between inverter and system manager
Checks
- Ensure that the connection to the system manager (e.g. Sunny Home Manager) is intact
- Check that no cables are damaged and no plugs have been pulled
- Confirm the fall-back active power limit is acceptable until communication is restored
Parts
- communication
- system manager
Citations
https://files.sma.de/downloads/STP3-6-3AV-40-BE-en-22.pdf
type: manual · retrieved: 2026-11-21 · locator: p. 98
Explanation: Communication to the system control absent. Depending on the fallback setting, either the last received values will be retained or the active power will be limited to the set percentage value of the inverter nominal power.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.