9007 — SMA
Abort self-test
severity: warningconfidence: verifiedkind: error1 citation(s)
Scope: SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)
Meaning
The self-test that the inverter runs as part of the grid-connection configuration was terminated before it completed. SMA asks for the AC connection to be checked for correctness and for the self-test to be restarted.
Likely causes
- Self-test interrupted by the installer
- AC connection not correct, so the test could not complete
Checks
- Ensure that the AC connection is correct
- Restart the self-test
Safety flags
- grid_tie
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- AC wiring
Citations
https://files.sma.de/downloads/STP3-6-3AV-40-BE-en-22.pdf
type: manual · retrieved: 2026-11-21 · locator: p. 99
Explanation: The self-test was terminated.