3802 — SMA
Residual current too high - check generator (DC overcurrent)
severity: stopconfidence: verifiedkind: error1 citation(s)
Scope: SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)
Meaning
Events 3801 and 3802 carry the event message 'Residual current too high / Check generator', and SMA's explanation is that there is an overcurrent at the DC input which makes the inverter briefly interrupt feed-in operation. The remedy given is to check that the PV array has been correctly rated and wired if the message appears frequently.
Likely causes
- PV array over-rated for the inverter's DC input
- Incorrect string wiring or paralleling
- DC-side fault or short circuit
Checks
- If the message is displayed frequently, ensure that the PV array has been correctly rated and wired
- Check the DC string wiring and the number of modules per string
- Contact SMA Service if the message persists after the array has been verified
Safety flags
- pv_dc
- dc_bus
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- PV strings
- DC cabling
Citations
https://files.sma.de/downloads/STP3-6-3AV-40-BE-en-22.pdf
type: manual · retrieved: 2026-11-21 · locator: p. 90
Explanation: Overcurrent at the DC input. The inverter briefly interrupts feed-in operation.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.