3303 — SMA
Unstable operation
severity: warningconfidence: verifiedkind: error1 citation(s)
Scope: SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)
Meaning
There is not enough power at the DC input for stable operation, so the inverter cannot connect to the utility grid. SMA's measures are to check that the PV array is correctly designed and free of errors and that it is not covered by snow or otherwise shaded.
Likely causes
- PV array too small or too lightly irradiated for stable operation
- Snow cover or shading on the PV array
- Fault in the PV array or its wiring
Checks
- Ensure that the PV array is designed correctly
- Ensure that the PV array is not covered by snow or otherwise shaded
- Ensure that the PV array is free of errors
Safety flags
- pv_dc
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- PV modules
- DC cabling
Citations
https://files.sma.de/downloads/STP3-6-3AV-40-BE-en-22.pdf
type: manual · retrieved: 2026-11-21 · locator: p. 89
Explanation: There is not enough power at the DC input of the inverter for stable operation. The inverter cannot connect to the utility grid.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.