3303 — SMA

Unstable operation

severity: warningconfidence: verifiedkind: error1 citation(s)

Scope: SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)

Meaning

There is not enough power at the DC input for stable operation, so the inverter cannot connect to the utility grid. SMA's measures are to check that the PV array is correctly designed and free of errors and that it is not covered by snow or otherwise shaded.

Likely causes

Checks

Safety flags

Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.

Parts

Citations

https://files.sma.de/downloads/STP3-6-3AV-40-BE-en-22.pdf

type: manual · retrieved: 2026-11-21 · locator: p. 89

Explanation: There is not enough power at the DC input of the inverter for stable operation. The inverter cannot connect to the utility grid.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.