1001 — SMA

L / N swapped

severity: stopconfidence: verifiedkind: error1 citation(s)

Scope: SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)

Meaning

The L and N connections have been installed the wrong way round. SMA asks the installer to check the AC wiring between the inverter and the feed-in meter and to measure the AC voltages at the inverter connection, and to contact Service if the message persists.

Likely causes

Checks

Safety flags

Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.

Parts

Citations

https://files.sma.de/downloads/STP3-6-3AV-40-BE-en-22.pdf

type: manual · retrieved: 2026-11-21 · locator: p. 87

Explanation: Incorrect installation of the L / N connection.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.