Grid incident - utility grid down / AC cable damaged / grid voltage too low
severity: degradedconfidence: verifiedkind: error1 citation(s)
Scope: SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)
Meaning
Events 202, 203, 205 and 206 report that the utility grid has been disconnected, the AC cable is damaged, or the grid voltage at the connection point is too low, so the inverter has stopped feeding in. SMA directs the installer to check the miniature circuit breaker, the AC cable and the configured country standard, then to verify the grid voltage and involve the grid operator if the local grid is responsible.
Likely causes
- Utility grid outage or miniature circuit breaker switched off
- Damaged or incorrectly connected AC cable
- Grid voltage below the permissible range at the connection point
- Wrong country standard configured
Checks
- Ensure that the miniature circuit breaker is switched on
- Ensure that the AC cable is not damaged and is connected correctly
- Ensure that the country standard has been configured correctly
- Check whether the grid voltage is permanently within the permissible range; if not, contact the grid operator
Safety flags
- grid_tie
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- AC wiring
- AC circuit breaker
Citations
https://files.sma.de/downloads/STP3-6-3AV-40-BE-en-22.pdf
type: manual · retrieved: 2026-11-21 · locator: p. 82
Explanation: The utility grid has been disconnected, the AC cable is damaged or the grid voltage at the connection point of the inverter is too low. The inverter has disconnected from the utility grid.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.