6509 — SMA

Self-diagnosis - overtemperature

severity: degradedconfidence: verifiedkind: error1 citation(s)

Scope: SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)

Meaning

Events 6501, 6502 and 6509 all mean the inverter has switched off because of excessive temperature. SMA's measures are to clean the cooling fins and air ducts with a soft brush, ensure the enclosure is sufficiently ventilated, keep it out of direct solar irradiation and make sure the maximum ambient temperature is not exceeded.

Likely causes

Checks

Parts

Citations

https://files.sma.de/downloads/STP3-6-3AV-40-BE-en-22.pdf

type: manual · retrieved: 2026-11-21 · locator: p. 93

Explanation: The inverter has switched off due to excessive temperature.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.