6802 — SMA
Self-diagnosis - input A / input B defective (polarity error)
severity: stopconfidence: verifiedkind: error1 citation(s)
Scope: SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)
Meaning
Events 6801 and 6802 are reported as 'Self-diagnosis > Input A defective' and events 6901 and 6902 as 'Self-diagnosis > Input B defective'; the explanation SMA gives for all four is a polarity error on the inverter. The measures are to check whether a string is connected to input A (or B) and to contact Service.
Likely causes
- PV string connected with reversed polarity to the DC input
- No string connected to the input although one is configured
- Input-stage fault on the DC input
Checks
- Check whether a string is connected to the input and that its polarity is correct
- Contact SMA Service if the message persists
Safety flags
- pv_dc
- dc_bus
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- PV strings
- DC input
Citations
https://files.sma.de/downloads/STP3-6-3AV-40-BE-en-22.pdf
type: manual · retrieved: 2026-11-21 · locator: p. 95
Explanation: Polarity error on the inverter.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.