3601 — SMA
High leakage current - check generator
severity: stopconfidence: verifiedkind: error1 citation(s)
Scope: SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)
Meaning
The leakage current of the inverter and the PV module is too high: there is a ground fault, a residual current or a malfunction. The inverter interrupts feed-in operation immediately after the threshold is exceeded and reconnects automatically once the fault is cleared; SMA's measure is to check the PV system for ground faults.
Likely causes
- Ground fault in the PV array
- Residual current through damaged insulation
- Malfunction in the inverter's residual-current monitoring
Checks
- Disconnect the inverter from voltage sources before working on the array
- Check the PV system for ground faults
- Confirm the fault is cleared before the inverter reconnects on its own
Safety flags
- dc_arc
- pv_dc
- grid_tie
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- PV modules
- DC cabling
- RCD
Citations
https://files.sma.de/downloads/STP3-6-3AV-40-BE-en-22.pdf
type: manual · retrieved: 2026-11-21 · locator: p. 89
Explanation: The leakage current of the inverter and the PV module is too high. There is a ground fault, a residual current or a malfunction.