3601 — SMA

High leakage current - check generator

severity: stopconfidence: verifiedkind: error1 citation(s)

Scope: SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)

Meaning

The leakage current of the inverter and the PV module is too high: there is a ground fault, a residual current or a malfunction. The inverter interrupts feed-in operation immediately after the threshold is exceeded and reconnects automatically once the fault is cleared; SMA's measure is to check the PV system for ground faults.

Likely causes

Checks

Safety flags

Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.

Parts

Citations

https://files.sma.de/downloads/STP3-6-3AV-40-BE-en-22.pdf

type: manual · retrieved: 2026-11-21 · locator: p. 89

Explanation: The leakage current of the inverter and the PV module is too high. There is a ground fault, a residual current or a malfunction.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.