Fronius

48 cited fault codes · owned by SolarDesk.

CodeTitleSeverityConfidenceCitations
101Grid voltage not within admissible rangedegradedverified1
104Grid frequency not within admissible rangedegradedverified1
107No AC grid detecteddegradedverified1
108Islanding detecteddegradedverified1
221Grid voltage L1/N exceeds admissible limitsdegradedverified1
222Grid voltage L1/N below admissible limitsdegradedverified1
223Grid voltage L2/N exceeds admissible limitsdegradedverified1
224Grid voltage L2/N below admissible limitsdegradedverified1
225No grid voltage detecteddegradedverified1
301Overcurrent (AC)degradedverified1
302Overcurrent (DC)degradedverified1
303Over-temperature AC sidedegradedverified1
304Over-temperature DC sidedegradedverified1
306POWER LOWdegradedverified1
307DC LOWdegradedverified1
401No internal communication with power stage setdegradedverified1
402Communication with EEPROM not possibledegradedverified1
403EEPROM faultydegradedverified1
406Temperature sensor(s) defectivedegradedverified1
407Temperature sensor at cooling element defectivedegradedverified1
408Direct current feed indegradedverified1
409No +15V supply for control electronicsdegradedverified1
410Service plug not in original positiondegradedverified1
412Fixed voltage selected instead of MPP operationdegradedvendor1
413Control problemsdegradedverified1
414EEPROM faulty (memory deleted)degradedverified1
417Two power stage sets with the same PCB numberdegradedverified1
419Identical software serial number on power stage setsdegradedverified1
421PCB number set incorrectlydegradedverified1
425Communication with power stage set not possibledegradedverified1
434Ground fault detecteddegradedverified1
446Internal communication error with NL-MON plug-in carddegradedverified1
447GFDI stopped grid monitoringdegradedverified1
448Neutral conductor N not connecteddegradedverified1
501One of the two fans is defectivedegradedverified1
504No Solar Net communication possibledegradedverified1
505EEPROM faulty (setup data lost)degradedvendor1
506EEPROM faulty (total data lost)degradedvendor1
507EEPROM faulty (day/year data lost)degradedvendor1
508Inverter address incorrectdegradedverified1
50924h no feed indegradedverified1
510EEPROM faulty (SMS settings defaulted)degradedvendor1
511EEPROM faulty (sensor card defaulted)degradedvendor1
512Too many power stage sets in the systemdegradedverified1
514No communication with one power stage setdegradedverified1
515Faulty plug connectionsdegradedverified1
516Status code present for one power stage setdegradedverified1
517Change of master has taken placedegradedverified1