515 — Fronius
Faulty plug connections
severity: degradedconfidence: verifiedkind: error1 citation(s)
Scope: Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters
Meaning
The DC/AC or DC/DC temperature sensor is faulty, or the service jumper is not connected.
Likely causes
- Faulty temperature sensor plug
- Service jumper on wrong position
Checks
- Check plug-in connections; contact a Fronius-trained technician if it persists
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Citations
https://www.fronius.com/~/downloads/Solar%20Energy/Operating%20Instructions/42,0410,1089.pdf
type: manual · retrieved: 2026-11-21 · locator: p. 92
Faulty plug connections
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.