412 — Fronius
Fixed voltage selected instead of MPP operation
severity: degradedconfidence: vendorkind: error1 citation(s)
Scope: Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters
Meaning
The inverter is configured for fixed-voltage operation instead of MPP voltage operation, which can conflict with the installation.
Likely causes
- Wrong operating-mode setting (fixed voltage vs MPP)
Checks
- Check the operating-mode setting against the installation
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Citations
https://www.fronius.com/~/downloads/Solar%20Energy/Operating%20Instructions/42,0410,1089.pdf
type: manual · retrieved: 2026-11-21 · locator: p. 88
The "fixed voltage" setting has been selected instead of MPP voltage operation and the voltage is set to too low a value, or DC voltage exceeds allowable limits.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.