Mixer Tank Low
severity: stopconfidence: verifiedkind: fault1 citation(s)
Scope: Videojet 1580 / 1860 / 1880
Meaning
The mixer tank fluid level is below the allowed limit.
Likely causes
- Ink cartridge empty or missing
- Wrong or expired cartridge
- Solvent control module failure
- Bad level sensor or IMB
- Clogged venturi
Checks
- Check the ink cartridge and fit a replacement if needed
Parts
- ink cartridge
- level sensor
- solvent control module
Citations
type: manual · retrieved: 2026-11-21 · locator: p. 9-17
(E15064) Mixer Tank Low