E15007 — Videojet
Viscometer Fill Time Too Long
severity: stopconfidence: verifiedkind: fault1 citation(s)
Scope: Videojet 1580 / 1860 / 1880
Meaning
The viscometer failed to fill in time, so viscosity cannot be monitored.
Likely causes
- Clogged viscometer restrictor
- High-level probe fault
- Valve fault
- Blocked vent
- Defective IMB
Checks
- Run a hardware self-test on the ink system components
Parts
- viscometer
- valve
- ink management board
Citations
type: manual · retrieved: 2026-11-21 · locator: p. 9-13
(E15007) Viscometer Fill Time Too Long
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: PackDesk.