Printhead 1 Valve Current Offset Out of Range
severity: stopconfidence: verifiedkind: fault1 citation(s)
Scope: Videojet 1580 / 1860 / 1880
Meaning
The printhead valve current offset measured at start-up is outside tolerance.
Likely causes
- Erroneous offset calculated at boot
- Environmental extreme
- Short in one or more valves
- Defective MCB
Checks
- Power-cycle to reset the offset
- Run a hardware self-test or valve test
Parts
- printhead valves
- main control board
Citations
type: manual · retrieved: 2026-11-21 · locator: p. 9-7
(E10672) Printhead 1 Valve Current Offset Out of Range
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: PackDesk.