E10671 — Videojet
Ink System Valve Current Offset Out of Range
severity: stopconfidence: verifiedkind: fault1 citation(s)
Scope: Videojet 1580 / 1860 / 1880
Meaning
The ink-system valve current offset measured at start-up is outside tolerance.
Likely causes
- Erroneous offset calculated at boot
- Environmental extreme
- Short in one or more valves
- Defective IMB
Checks
- Power-cycle to reset the offset
- Run a hardware self-test or valve test
Parts
- ink system valves
- ink management board
Citations
type: manual · retrieved: 2026-11-21 · locator: p. 9-7
(E10671) Ink System Valve Current Offset Out of Range
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: PackDesk.