VE.Bus Error 8 — Victron
Ground relay test failed
severity: degradedconfidence: verifiedkind: error1 citation(s)
Scope: Victron MultiPlus / Quattro / MultiPlus-II / EasySolar-II (VE.Bus inverter/charger)
Meaning
A failed self-test of the internal ground relay (MultiPlus-II / EasySolar-II). The ground relay is tested to close during inverting and to open when switching to mains.
Likely causes
- Neutral-out externally tied to ground
- Intentional Neutral bypass not configured in software
- Leakage or short in the AC loads
- Faulty ground relay or detection circuit
Checks
- Check Neutral-out is not externally tied to ground
- Check the neutral path configuration matches the grid code
- Isolate loads (open breakers) and retest grid switch-over
- Replace the unit if a ground-relay error repeats
Safety flags
- dc_bus
- grid_tie
- pv_dc
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- ground relay
- AC wiring
Citations
https://www.victronenergy.com/live/ve.bus:ve.bus_error_codes
type: vendor_kb · retrieved: 2026-11-21 · locator: § Error 8 - Ground relay test failed
This error indicates a failed self-test of the MultiPlus-II or EasySolar-II internal 1 ground relays.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.