VE.Bus Error 18 — Victron

AC over-voltage on switched-off slave output

severity: degradedconfidence: verifiedkind: error1 citation(s)

Scope: Victron MultiPlus / Quattro / MultiPlus-II / EasySolar-II (VE.Bus inverter/charger)

Meaning

AC voltage is present on a slave's AC output while it is switched off; there can never be voltage there, so the AC wires are likely swapped.

Likely causes

Checks

Safety flags

Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.

Parts

Citations

https://www.victronenergy.com/live/ve.bus:ve.bus_error_codes

type: vendor_kb · retrieved: 2026-11-21 · locator: § Error 18 - AC Over-voltage on the output of a slave while switched off

Solution: check if AC wires are not swapped by accident. There can never be voltage on the AC out when a unit is switched off. Recovery: system remains off until restarted.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.