VE.Bus Error 10 — Victron
System time synchronisation problem
severity: degradedconfidence: verifiedkind: error1 citation(s)
Scope: Victron MultiPlus / Quattro / MultiPlus-II / EasySolar-II (VE.Bus inverter/charger)
Meaning
A time synchronisation problem, typically transient during system restart; often follows Error 1.
Likely causes
- Transient during restart
- Blown DC fuse on one or more units (mains fails)
Checks
- Ignore if only seen during restart
- Check DC fuses on all units
Safety flags
- dc_bus
Parts
- DC fuse
Citations
https://www.victronenergy.com/live/ve.bus:ve.bus_error_codes
type: vendor_kb · retrieved: 2026-11-21 · locator: § Error 10 - System time synchronisation problem
This typically happens during a system restart, and is then not a real error; no need to investigate.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.