Err 72 — Victron
Phase rotation
severity: degradedconfidence: vendorkind: error1 citation(s)
Scope: Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC
Meaning
The phase order is not correct (L1->L2->L3) on a three-phase system; the inverters stay operational but will not connect to the grid.
Likely causes
- Incorrect phase order in the installation
Checks
- Check and correct the phase order to L1->L2->L3
Safety flags
- grid_tie
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- AC wiring
Citations
https://www.victronenergy.com/live/mppt-error-codes
type: vendor_kb · retrieved: 2026-11-21 · locator: § Err 72 - Phase rotation
Applies to Inverter RS and Multi RS models.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.