Err 68 — Victron
Network misconfigured
severity: degradedconfidence: vendorkind: error1 citation(s)
Scope: Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC
Meaning
The charger detects multiple conflicting network sources (VE.Can and VE.Direct) with the same priority sending the same information.
Likely causes
- Both VE.Direct and VE.Can connected at the same time
- Firmware older than v1.48 (SmartSolar VE.Direct)
Checks
- Update firmware
- Remove one of the two cables (VE.Direct or VE.Can)
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- communication cabling
Citations
https://www.victronenergy.com/live/mppt-error-codes
type: vendor_kb · retrieved: 2026-11-21 · locator: § Err 68 - Network misconfigured
Applies to SmartSolar/BlueSolar MPPTs VE.Can (FW version v1.04 or higher) and SmartSolar VE.Direct MPPTs (FW version v1.47).
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.