Err 67 — Victron

BMS connection lost

severity: degradedconfidence: verifiedkind: error1 citation(s)

Scope: Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC

Meaning

The charger is configured to be controlled by a BMS but is not receiving BMS messages, so it reduces output to the battery base voltage as a safety measure.

Likely causes

Checks

Safety flags

Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.

Parts

Citations

https://www.victronenergy.com/live/mppt-error-codes

type: vendor_kb · retrieved: 2026-11-21 · locator: § Err 67 - BMS Connection lost

This error shows when the charger is configured to be controlled by a BMS, but does not receive any BMS control messages.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.