Err 67 — Victron
BMS connection lost
severity: degradedconfidence: verifiedkind: error1 citation(s)
Scope: Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC
Meaning
The charger is configured to be controlled by a BMS but is not receiving BMS messages, so it reduces output to the battery base voltage as a safety measure.
Likely causes
- Disconnected or faulty BMS communication cable
- BMS switched off or faulty
Checks
- Check the connection between the charger and the BMS
- Reconfigure to standalone mode if the charger is no longer used with a BMS
Safety flags
- lithium_battery
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- BMS
- communication cable
Citations
https://www.victronenergy.com/live/mppt-error-codes
type: vendor_kb · retrieved: 2026-11-21 · locator: § Err 67 - BMS Connection lost
This error shows when the charger is configured to be controlled by a BMS, but does not receive any BMS control messages.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.