Err 6 — Victron
Remote battery voltage sense failure
severity: degradedconfidence: verifiedkind: error1 citation(s)
Scope: Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC
Meaning
The remote battery voltage sense input is invalid, most commonly because the V-sense connector is wired in reverse polarity.
Likely causes
- V-sense connector wired with reversed polarity
- Faulty sense wiring
Checks
- Check the V-sense connector polarity against the battery terminals
- Reconnect and confirm the reading
Safety flags
- lithium_battery
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- voltage sense wiring
Citations
https://www.victronenergy.com/live/mppt-error-codes
type: vendor_kb · retrieved: 2026-11-21 · locator: § Err 6, Err 7 - Remote battery voltage sense failure
Check if the V-sense connector is properly connected to the battery terminals. Most likely cause: the remote V-sense connector is connected in reverse polarity to the BAT+ or BAT- terminals.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.