Err 5 — Victron
Remote temperature sensor failure (connection lost)
severity: degradedconfidence: verifiedkind: error1 citation(s)
Scope: Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC
Meaning
The charger has lost connection to the remote temperature sensor it was previously reading.
Likely causes
- Loose or disconnected T-sense wiring
- Failed temperature sensor
Checks
- Check the T-sense connector and cable
- Reconnect and confirm the reading returns in VictronConnect
Parts
- temperature sensor
Citations
https://www.victronenergy.com/live/mppt-error-codes
type: vendor_kb · retrieved: 2026-11-21 · locator: § Err 5 - Remote temperature sensor failure (connection lost)
Check if the T-sense connector is properly connected to a remote temperature sensor. This error will not auto-reset.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.