Err 43 — Victron

Ground fault detected

severity: degradedconfidence: verifiedkind: error1 citation(s)

Scope: Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC

Meaning

The voltage between Neutral and Ground is too high. On grid-connected systems this usually means the installation ground is missing/incorrect or Line and Neutral are swapped; on island systems the ground relay may be damaged. It does not auto-reset.

Likely causes

Checks

Safety flags

Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.

Parts

Citations

https://www.victronenergy.com/live/mppt-error-codes

type: vendor_kb · retrieved: 2026-11-21 · locator: § Err 43 - Ground fault detected

The voltage difference between Neutral and Ground is too high.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.