Ground fault detected
severity: degradedconfidence: verifiedkind: error1 citation(s)
Scope: Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC
Meaning
The voltage between Neutral and Ground is too high. On grid-connected systems this usually means the installation ground is missing/incorrect or Line and Neutral are swapped; on island systems the ground relay may be damaged. It does not auto-reset.
Likely causes
- Missing or incorrectly connected ground wire
- Line and Neutral swapped in the installation
- Damaged ground relay (island operation)
Checks
- Check the installation ground and Line/Neutral wiring
- Restart the unit with the power switch after correcting the wiring
Safety flags
- dc_arc
- grid_tie
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- ground wiring
- ground relay