Err 38 — Victron
PV input shutdown (battery over-charge protection)
severity: degradedconfidence: verifiedkind: error1 citation(s)
Scope: Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC
Meaning
The PV input was internally shorted to protect the battery from over-charging. Check firmware and the battery voltage setting before other troubleshooting.
Likely causes
- Battery voltage (12/24/36/48 V) set incorrectly
- Another device on the battery configured to a higher voltage
- Outdated firmware
Checks
- Update to the latest firmware
- Verify the battery voltage setting in VictronConnect
- Disconnect panels then battery, wait 3 minutes, reconnect battery then panels
Safety flags
- dc_arc
- lithium_battery
- pv_dc
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- battery
- PV input
Citations
https://www.victronenergy.com/live/mppt-error-codes
type: vendor_kb · retrieved: 2026-11-21 · locator: § Err 38, Err 39 and Err 80 to Err 87 - PV Input shutdown
When these errors show, the PV Input is internally shorted in order to protect the battery from over-charging.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.