PV over-current

severity: degradedconfidence: verifiedkind: error1 citation(s)

Scope: Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC

Meaning

The solar array current exceeded the rated input current, or an internal fault occurred. Persistent failure after a power-cycle suggests a faulty controller.

Likely causes

Checks

Safety flags

Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.

Parts

Citations

https://www.victronenergy.com/live/mppt-error-codes

type: vendor_kb · retrieved: 2026-11-21 · locator: § Err 34 - PV over-current

The current from the solar-panel array has exceeded the rated current limit.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.