Err 33 — Victron
PV over-voltage
severity: degradedconfidence: verifiedkind: error1 citation(s)
Scope: Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC
Meaning
The PV open-circuit voltage is critical for this charger (too high for its rating); the error resets once PV voltage drops to a safe level.
Likely causes
- PV array open-circuit voltage too high for the charger
- Too many panels in series
Checks
- Check the PV array configuration against the charger's max PV voltage
- Re-organise panels (fewer in series) if required
Safety flags
- dc_arc
- pv_dc
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- PV array
Citations
https://www.victronenergy.com/live/mppt-error-codes
type: vendor_kb · retrieved: 2026-11-21 · locator: § Err 33 - PV over-voltage
This error will auto-reset after PV-voltage has dropped to safe limit.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.