Err 3 — Victron
Remote temperature sensor failure
severity: degradedconfidence: verifiedkind: error1 citation(s)
Scope: Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC
Meaning
The remote temperature sensor reading is invalid, usually because the T-sense connector is wired to the battery terminal instead of a temperature sensor.
Likely causes
- T-sense connector connected to BAT+ or BAT- instead of a temperature sensor
- Faulty sensor or wiring
Checks
- Check the T-sense connector is on a temperature sensor, not a battery terminal
- Reconnect correctly and confirm the error clears
Safety flags
- lithium_battery
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- temperature sensor
Citations
https://www.victronenergy.com/live/mppt-error-codes
type: vendor_kb · retrieved: 2026-11-21 · locator: § Err 3, Err 4 - Remote temperature sensor failure
Check if the T-sense connector is properly connected to a remote temperature sensor.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.