Err 29 — Victron
Over-charge protection
severity: degradedconfidence: verifiedkind: error1 citation(s)
Scope: Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC
Meaning
The charger disconnected the battery to protect it from over-charging; it resets once battery voltage drops below float.
Likely causes
- Oversized PV array wired with too many panels in series
- Battery settings (absorption/float) not matching the installation
- Another charger raising the battery voltage
Checks
- Check PV array configuration and re-wire panels in parallel to reduce voltage if needed
- Verify absorption and float voltage settings match the battery
- Check for other chargers on the battery
Safety flags
- lithium_battery
- pv_dc
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- battery
- PV array
Citations
https://www.victronenergy.com/live/mppt-error-codes
type: vendor_kb · retrieved: 2026-11-21 · locator: § Err 29 - Over-Charge protection
This error will auto-reset once the battery voltage drops below the float voltage.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.