Err 27 — Victron
Charger short circuit
severity: degradedconfidence: verifiedkind: error1 citation(s)
Scope: Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC
Meaning
An over-current condition on the battery side, for example when a battery is attached via a contactor or the charger starts into an inverter with large input capacitance. It auto-resets; persistent failure suggests a faulty controller.
Likely causes
- Battery connected through a contactor
- Charger starting without battery into a high-capacitance inverter
- Faulty controller
Checks
- Let it auto-reset; if it does not, isolate all power, wait 3 minutes, repower
- Contact the dealer if it persists
Safety flags
- dc_arc
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- charge controller
Citations
https://www.victronenergy.com/live/mppt-error-codes
type: vendor_kb · retrieved: 2026-11-21 · locator: § Err 27 - Charger short circuit
This condition indicates an over-current condition on the battery side.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.